Product Description
Details
Power Supply/Charger:
• 9.4 amp @ 24VDC.
• 115VAC 60Hz, 6.5 amp input.
• Input fuse rated @ 3.5 amp.
• Filtered and electronically regulated outputs.
• Built-in charger for sealed lead acid or gel type batteries.
• Maximum charge current .7 amp.
• Automatic switch over to stand-by battery when AC fails.
• Zero voltage drop when unit switches over to battery backup
(AC failure condition).
• Short circuit and thermal onerload protection with auto reset.
• AC input and DC output LED indicators.
• AC fail supervision (form "C" contact).
• Battery fail and battery presence supervision (form "C" contact).
Access Power Controller:
• Sixteen (16) Access Control System trigger inputs.
• Input options:
a) Sixteen (16) normally open (NO) inputs.
b) Sixteen (16) open collector inputs.
c) Any combination of the above.
• Sixteen (16) independently controlled fuse protected outputs.
• Output options:
a) Sixteen (16) Fail-Safe and/or Fail-Secure power outputs.
b) Sixteen (16) form “C” 5 amp rated relay outputs.
c) Any combination of the above.
• Sixteen (16) auxiliary power outputs (unswitched) (outputs are rated 3.5 amp).
• Power supply input options:
a) One (1) common power input for either ACM8 and lock power (factory installed).
b) Two (2) isolated power inputs (external power supply is required). (current is determined by the power supply connected, not to exceed a maximum of 10 amp total).
• ACM8 board's main fuse is rated @ 10 amp.
• Red LEDs indicate outputs are triggered (relays energized).
• Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the Sixteen (16) outputs.
• Fire Alarm disconnect input options:
a) Normally open (NO) or normally closed (NC) dry contact input.
b) Polarity reversal input from FACP signaling circuit.
• Alarm output relay indicates that FACP input is triggered (form “C” contact rated @ 1 amp 28VDC not evaluated by UL).
• Green LED indicates FACP disconnect is triggered.
Additional Information
Additional Information
| Manufacturer | Altronix |
|---|---|
| Model | MAXIMAL7 |
| Dimensions | 26”H x 19”W x 6.25”D 1/2" and 3/4" combination knockouts Accommodates up to four (4) 12VDC/12AH batteries |
| Input Voltage | 115VAC 60Hz, 6.5 amp input |
| U.L. Listed | UL Listed for Access Control Systems (UL294), CUL Listed - CSA Standard C22.2 No.205-M1983, Signal Equipment. |
| CA State Fire Marshal | CSFM - California State Fire Marshal Approved. |
| Warranty | Lifetime Warranty |
| Weight | 20.0000 |
Reviews
Write Your Own Review
Product Tags
Product Questions
Questions on Altronix MAXIMAL7 Access Power Controller
No questions asked yet
Ask Your Own Question
Product Downloads
![]() |
Altronix MAXIM7 Installation Instructions (Size: 596.2 KB) |
![]() |
Altronix MAXIM7 Specification Sheet (Size: 230.7 KB) |