(888) 209-8167
M-F 9AM-5PM EST

You have no items in your shopping cart.

Altronix MAXIMAL33 Access Power ControllerAltronix MAXIMAL33 Access Power Controller
Move your mouse over image or click to enlarge

Altronix MAXIMAL33 Access Power Controller

Be the first to review this product

This unit distributes and switches power to access control systems and accessories. It converts a 115VAC 60Hz input into sixteen (16) independently controlled 12VDC and/or 24VDC fuse protected outputs. These power outputs can be converted to dry form “C” contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. The unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the sixteen (16) outputs.

Availability: In stock

$605.93

Free Ground Shipping on domestic orders over $200

Priority orders placed before 12PM PST will be shipped the same day. Standard orders will be shipped within 24 hours.

Most items (excluding special orders) can be returned or exchanged within 30 days. Please see our Return Policy for more details.

Have Questions? Chat with us at the bottom of the screen or call us at (888) 209-8167

Product Description

Details


Power Supply/Charger:

• Output Power Options:
a) 5.5 amp @ 12VDC plus 5.5 amp @ 12VDC.
b) 5.7 amp @ 24VDC plus 5.7 amp @ 24VDC.
c) 5.5 amp @ 12VDC plus 5.7 amp @ 24VDC.
• 115VAC 60Hz, 7.0 amp input.
• Input fuse rated @ 3.5 amp.
• Filtered and electronically regulated outputs.
• Built-in charger for sealed lead acid or gel type batteries.
• Maximum charge current .7 amp.
• Automatic switch over to stand-by battery when AC fails.
• Zero voltage drop when unit switches over to battery backup (AC failure condition).
• Short circuit and thermal onerload protection with auto reset.
• AC input and DC output LED indicators.
• AC fail supervision (form "C" contact).
• Battery fail and battery presence supervision (form "C" contact).

Access Power Controller:

• Sixteen (16) Access Control System trigger inputs.
• Input options:
a) Sixteen (16) normally open (NO) inputs.
b) Sixteen (16) open collector inputs.
c) Any combination of the above.
• Sixteen (16) independently controlled fuse protected outputs.
• Output options:
a) Sixteen (16) Fail-Safe and/or Fail-Secure power outputs.
b) Sixteen (16) form “C” 5 amp rated relay outputs.
c) Any combination of the above.
• Sixteen (16) auxiliary power outputs (unswitched) (outputs are rated 3.5 amp).
• Power supply input options:
a) One (1) common power input for either ACM8 and lock power (factory installed).
b) Two (2) isolated power inputs (external power supply is required). (current is determined by the power supply connected, not to exceed a maximum of 10 amp total).
• ACM8 board's main fuse is rated @ 10 amp.
• Red LEDs indicate outputs are triggered (relays energized).
• Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the Sixteen (16) outputs.
• Fire Alarm disconnect input options:
a) Normally open (NO) or normally closed (NC) dry contact input.
b) Polarity reversal input from FACP signaling circuit.
• Alarm output relay indicates that FACP input is triggered (form “C” contact rated @ 1 amp 28VDC not evaluated by UL).
• Green LED indicates FACP disconnect is triggered.

Additional Information

Additional Information

Manufacturer Altronix
Model MAXIMAL33
Dimensions 26”H x 19”W x 6.25”D
1/2" and 3/4" combination knockouts
Accommodates up to four (4) 12VDC/12AH batteries
Outputs Selectable 24VDC or 12VDC
Input Voltage 115VAC 60Hz, 7.0 amp input.
U.L. Listed UL Listed for Access Control Systems (UL294),
CUL Listed - CSA Standard C22.2 No.205-M1983, Signal Equipment.
CA State Fire Marshal CSFM - California State Fire Marshal Approved.
Warranty Lifetime Warranty
Weight 20.0000

Reviews

Write Your Own Review

You're reviewing: Altronix MAXIMAL33 Access Power Controller

Product Tags

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

Product Questions

Questions on Altronix MAXIMAL33 Access Power Controller

No questions asked yet

Ask Your Own Question